This protector will stop electrical transients such as spikes, surges and noise from

damaging strain gage load cells. Excitation voltage can be 18 VDC or +/-9 VDC or 9

VAC. This unit will clamp the excitation voltage to 20 VDC between + and - excitation

terminals, 75 VDC between any terminal and earth ground. Three active protection

stages on each of four lines. One active protection stage on the shield. Response time

on 20 VDC stage is 5 nanoseconds. Response time on 75 VDC stage is 100

nanoseconds. Resistance to ground is 7500 megohms minimum. Grounding is through a

1/4" lug to a 20 ft insulated #10 AWG ground wire(included). Two nylon strain reliefs for

0.187"-0.312" dia cable. Chemically resistant PVC enclosure is gasketed NEMA 1,2,3 and

11 intended for indoor and outdoor service. It is not NEMA 4 (washdown) or NEMA 6

(submersion).



Call for prices on other enclosures.



4"W x 4"D x 2.5"H, 1.4 lb.

Part Number Capacity Weight SKU Available Price Buy

LCP-1 Transient protector 4 wire

Load cell transient protector 4 wire 3 Lbs 1957 1 $205.00 Buy

LCP-2 Transient protector 6 wire

Load cell transient protector 6 wire 2 Lbs 1752 Call $234.00 Buy